Sec. 25.1393 - Minimum intensities in any vertical plane of
forward and rear position lights.
Each position light intensity must equal or exceed the applicable values in the following table: ------------------------------------------------------------------------
Intensity,
Angle above or below the horizontal plane l
------------------------------------------------------------------------
0°..................................................... 1.00
0° to 5°.......................................... 0.90
5° to 10°......................................... 0.80
10° to 15°........................................ 0.70
15° to 20°........................................ 0.50
20° to 30°........................................ 0.30
30° to 40°........................................ 0.10
40° to 90°........................................ 0.05
------------------------------------------------------------------------
|