Sec. 29.1393 - Minimum intensities in any vertical plane of
forward and rear position lights.
Each position light intensity must equal or exceed the applicable values in the following table: ------------------------------------------------------------------------ Intensity, Angle above or below the horizontal plane I ------------------------------------------------------------------------ 0°..................................................... 1.00 0° to 5°.......................................... .90 5° to 10°......................................... .80 10° to 15°........................................ .70 15° to 20°........................................ .50 20° to 30°........................................ .30 30° to 40°........................................ .10 40° to 90°........................................ .05 ------------------------------------------------------------------------
|