Sec. 29.1395 - Maximum intensities in overlapping beams of
forward and rear position lights.
No position light intensity may exceed the applicable values in the following table, except as provided in §29.1389(b)(3). ------------------------------------------------------------------------ Maximum intensity ------------------------- Overlaps Area A Area B (candles) (candles) ------------------------------------------------------------------------ Green in dihedral angle L..................... 10 1 Red in dihedral angle R....................... 10 1 Green in dihedral angle A..................... 5 1 Red in dihedral angle A....................... 5 1 Rear white in dihedral angle L................ 5 1 Rear white in dihedral angle R................ 5 1 ------------------------------------------------------------------------Where -- (a) Area A includes all directions in the adjacent dihedral angle that pass through the light source and intersect the common boundary plane at more than 10 degrees but less than 20 degrees; and (b) Area B includes all directions in the adjacent dihedral angle that pass through the light source and intersect the common boundary plane at more than 20 degrees.
|