Sec. 27.1393 - Minimum intensities in any vertical plane of
forward and rear position lights.
Each position light intensity must equal or exceed the applicable values in the following table: ------------------------------------------------------------------------ Intensity, Angle above or below the horizontal plane l ------------------------------------------------------------------------ 0°..................................................... 1.00 0° to 5°.......................................... 0.90 5° to 10°......................................... 0.80 10° to 15°........................................ 0.70 15° to 20°........................................ 0.50 20° to 30°........................................ 0.30 30° to 40°........................................ 0.10 40° to 90°........................................ 0.05 ------------------------------------------------------------------------
|