Sec. 23.1391 - Minimum intensities in the horizontal plane of position lights.

Each position light intensity must equal or exceed the applicable values in the following table:

------------------------------------------------------------------------
                                        Angle from right or
                                       left of longitudinal    Intensity
   Dihedral angle (light included)      axis, measured from    (candles)
                                            dead ahead
------------------------------------------------------------------------
L and R (red and green).............  0° to 10°...          40
                                      10° to 20°..          30
                                      20° to 110°.           5
A (rear white)......................  110° to 180°          20
------------------------------------------------------------------------